Get 12% OFF Automatically When You Spend $2,000 or More No Code Required
Get 12% OFF Automatically When You Spend $2,000 or More No Code Required

FREE SHIPPING ON ORDERS OVER $1K

EXPERT LIGHTING ADVICE

VALUE ENGINEERED QUOTES

ROI ANALYSIS AND DESIGN SUPPORT

Wall Sconces

Products List

Sort By:

Display Type:
Filters
  • Product
  • Qty in Cart
  • Quantity
  • Price
  • Subtotal
  • Total: items /

Adding your products to cart

Wall Sconces That Meet ADA Protrusion Rules

Most retailers sell wall sconces on looks alone. In a commercial corridor, looks are only half the spec. The ADA limits wall mounted objects installed between 27 and 80 inches above the finished floor to a maximum protrusion of 4 inches into any circulation path. A sconce that projects 6 inches from the wall of a hotel hallway or apartment corridor is a code violation waiting for an inspection. RelightDepot carries low profile, ADA compliant sconce options alongside deeper decorative fixtures, and calls out protrusion depth so specifiers can filter for corridor duty before ordering.

That code awareness matters because sconces do real work in multifamily, hospitality, and healthcare projects: they carry corridor light levels between ceiling fixtures, soften lobbies and waiting areas, and flank vanity mirrors in guest baths. The selection here runs from architectural wall mounted cylinders with up, down, or up and down distributions to decorative wall sconce styles coordinated with interior finishes.

Mounting Height and Corridor Spacing

Two numbers drive most sconce layouts: height to the fixture center and spacing along the run. Use the conventions below as a starting point, then verify against the photometrics of the specific fixture.

ApplicationMounting Height (to Center)Typical SpacingNotes
Multifamily and hotel corridors66 to 72 in8 to 12 ft on centerConfirm 4 in maximum protrusion; alternate sides for even coverage
Lobbies and lounges60 to 72 inPer designDeeper decorative fixtures acceptable outside circulation paths
Vanity and bath areas60 to 65 in beside mirrorPairs flanking the mirrorDamp rated fixture required; see the bath subcategory
Stairwells and landingsPer code egress levelsEach landingConsider dedicated stairwell fixtures with integral sensors

For corridor spacing, work backward from the light level target. Many multifamily and hospitality corridors are designed to hold roughly 5 to 10 average footcandles; a sconce delivering 800 to 1,200 lumens every 8 to 12 feet is a common recipe at standard 8 to 9 foot ceilings. Long runs with higher targets need tighter spacing or higher output fixtures, which is where photometric files on the product pages earn their keep.

Damp and Wet Location Ratings

Location rating is the second spec decor retailers skip. A dry rated sconce belongs only in conditioned interior space. Damp rated fixtures handle humidity without direct water contact, covering restrooms, locker rooms, and covered exterior walkways and porte cocheres. Wet rated fixtures tolerate direct rain and washdown, which is what open exterior walls require. If a covered entry gets wind driven rain, treat it as wet. The rating appears on the fixture label and the spec sheet; when in doubt, defer to the spec sheet.

Sconce Styles: Cylinders, Decorative, and Plug In Options

Wall mounted cylinders are the workhorse sconce light for commercial interiors: clean geometry, no exposed lamps, and a choice of uplight, downlight, or both. Decorative sconces bring shades, cages, and finish detail where the fixture is part of the design intent. Most commercial work is hardwired, but a plug in wall sconce is a practical retrofit for guest rooms and offices where opening walls is off the table; check cord management before specifying them in public areas.

Browse Wall Mounted Cylinders and Decorative Wall Sconces for the two main families, or Bathroom and Vanity Lights for mirror side fixtures. For code driven egress lighting on stairs, see Stairwell Lighting, and for exterior walls head to Outdoor Wall Lights.

Frequently Asked Questions

ADA compliance for sconces comes down to protrusion depth. Fixtures mounted between 27 and 80 inches above the floor may extend no more than 4 inches from the wall into a circulation path such as a corridor or walkway. Sconces outside circulation paths, or mounted above 80 inches, are not bound by the 4 inch limit. Check the fixture's extension dimension on the spec sheet before specifying it for corridor use.

Typical practice puts the fixture center 60 to 72 inches above the finished floor. Corridors in multifamily and hospitality buildings usually land at 66 to 72 inches, while vanity sconces beside a mirror sit lower, around 60 to 65 inches so the light falls at face height. Ceiling height, fixture size, and distribution all shift the number, so treat these as starting points and verify with the fixture photometrics.

A common recipe for 8 to 9 foot corridors is one sconce every 8 to 12 feet, alternating sides of the hall, using fixtures in the 800 to 1,200 lumen range. That typically holds average light levels near the 5 to 10 footcandle range many corridor designs target. Higher targets, darker finishes, or taller ceilings call for tighter spacing or higher output fixtures.

Damp rated fixtures handle humidity and condensation without direct water contact, which covers restrooms, locker rooms, and fully covered exterior walkways. Wet rated fixtures tolerate direct rain, spray, and washdown, which open exterior walls require. If a covered area is exposed to wind driven rain, specify wet rated. The listing appears on the fixture label and spec sheet.

Downlight distributions put light on the floor, which suits corridors and task areas. Uplight washes the ceiling for a softer, indirect feel in lounges and lobbies. Up and down cylinders do both and create the strongest visual accent on the wall. In corridors, a distribution with a meaningful downward component keeps floor light levels up without adding fixtures.

They can be, in the right rooms. A plug in wall sconce avoids opening walls, which makes it a practical retrofit for hotel guest rooms, offices, and senior living units. In public circulation spaces most projects stay hardwired for a cleaner installation and to avoid cords in reach of the public. Confirm cord routing and receptacle placement before specifying plug in models at scale.

It depends on the job the sconce is doing. Corridor sconces carrying general light typically run 800 to 1,200 lumens each. Accent and decorative sconces in lobbies can run lower, 300 to 800 lumens, since they supplement ceiling lighting. Vanity sconces usually land between 450 and 800 lumens per fixture. Confirm delivered light levels with the fixture's photometric data rather than lamp lumens alone.